Our Home Inverter series embodies the pinnacle of innovation and reliability in home power solutions. Crafted to meet a range of energy needs, these inverters deliver seamless power management for the uninterrupted operation of essential appliances.
Each model in the series is engineered with cutting-edge technology, ensuring high performance and durability.
Ideal for eco-conscious users, it features advanced battery management and robust protection for reliable off-grid energy. Empower your off-grid lifestyle with the reliable and efficient power solutions offered by the Home Inverters Off-Grid Inverters. Choose from our range of models to suit your needs.
With a wide input voltage range of 90V-290V and a narrow mode range of 170V-270V, this inverter adapts seamlessly to various power sources.
Description | 850VA-12V | 1000VA-12V | 1400VA-12V | 2000VA-24V |
---|---|---|---|---|
Input Voltage (WIDE MODE) | 90V-290V ± 10V | 90V-290V ± 10V | 90V-290V ± 10V | 90V-290V ± 10V |
Input Range (NARROW MODE) | 170V-270V ± 10V | 170V-270V ± 10V | 170V-270V ± 10V | 170V-270V ± 10V |
Output Voltage on Mains Mode | Same as input | Same as input | Same as input | Same as input |
Output Voltage on Backup Mode | 210V+10%, -15% | 210V+10%, -15% | 210V+10%, -15% | 210V+10%, -15% |
Output Frequency in Backup Mode | 5OHz + O.1HZ | 5OHz + O.1HZ | 5OHz + O.1HZ | 5OHz + O.1HZ |
Switching from mains to Backup and from Backup to Mains | Automatic | Automatic | Automatic | Automatic |
Output Waveform on Mains Mode | Same as input | Same as input | Same as input | Same as input |
Output Waveform on Backup Mode | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave |
Battery Charging Current | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah |
Charger | CCCV | CCCV | CCCV | CCCV |
PCU Overload/PCU Short Circuit | 110% / 300% | 110% / 300% | 110% / 300% | 110% / 300% |
PCU Transfer Time | <=15msec | <=15msec | <=15msec | <=15msec |
Available Market | AF, ME, CIS |
The inverter ensures a stable output voltage of 210V in backup mode, with a pure sine wave output for optimal performance.
Description | 850VA-12V | 1000VA-12V | 1400VA-12V | 2000VA-24V |
---|---|---|---|---|
Input Voltage (WIDE MODE) | 90V-290V ± 10V | 90V-290V ± 10V | 90V-290V ± 10V | 90V-290V ± 10V |
Input Range (NARROW MODE) | 170V-270V ± 10V | 170V-270V ± 10V | 170V-270V ± 10V | 170V-270V ± 10V |
Output Voltage on Mains Mode | Same as input | Same as input | Same as input | Same as input |
Output Voltage on Backup Mode | 210V+10%, -15% | 210V+10%, -15% | 210V+10%, -15% | 210V+10%, -15% |
Output Frequency in Backup Mode | 5OHz + O.1HZ | 5OHz + O.1HZ | 5OHz + O.1HZ | 5OHz + O.1HZ |
Switching from mains to Backup and from Backup to Mains | Automatic | Automatic | Automatic | Automatic |
Output Waveform on Mains Mode | Same as input | Same as input | Same as input | Same as input |
Output Waveform on Backup Mode | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave |
Battery Charging Current | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah |
Charger | CCCV | CCCV | CCCV | CCCV |
PCU Overload/PCU Short Circuit | 110% / 300% | 110% / 300% | 110% / 300% | 110% / 300% |
PCU Transfer Time | <=15msec | <=15msec | <=15msec | <=15msec |
Available Market | AF, ME, CIS |
The inverter’s automatic switching capability and constant battery charging current of approximately 10% of the rated battery capacity ensure uninterrupted and efficient energy delivery.
Description | 850VA-12V | 1000VA-12V | 1400VA-12V | 2000VA-24V |
---|---|---|---|---|
Input Voltage (WIDE MODE) | 90V-290V ± 10V | 90V-290V ± 10V | 90V-290V ± 10V | 90V-290V ± 10V |
Input Range (NARROW MODE) | 170V-270V ± 10V | 170V-270V ± 10V | 170V-270V ± 10V | 170V-270V ± 10V |
Output Voltage on Mains Mode | Same as input | Same as input | Same as input | Same as input |
Output Voltage on Backup Mode | 210V+10%, -15% | 210V+10%, -15% | 210V+10%, -15% | 210V+10%, -15% |
Output Frequency in Backup Mode | 5OHz + O.1HZ | 5OHz + O.1HZ | 5OHz + O.1HZ | 5OHz + O.1HZ |
Switching from mains to Backup and from Backup to Mains | Automatic | Automatic | Automatic | Automatic |
Output Waveform on Mains Mode | Same as input | Same as input | Same as input | Same as input |
Output Waveform on Backup Mode | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave |
Battery Charging Current | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah |
Charger | CCCV | CCCV | CCCV | CCCV |
PCU Overload/PCU Short Circuit | 110% / 300% | 110% / 300% | 110% / 300% | 110% / 300% |
PCU Transfer Time | <=15msec | <=15msec | <=15msec | <=15msec |
Available Market | AF, ME, CIS |
This model is ideal for high-demand applications, ensuring reliable and efficient power management.
Description | 850VA-12V | 1000VA-12V | 1400VA-12V | 2000VA-24V |
---|---|---|---|---|
Input Voltage (WIDE MODE) | 90V-290V ± 10V | 90V-290V ± 10V | 90V-290V ± 10V | 90V-290V ± 10V |
Input Range (NARROW MODE) | 170V-270V ± 10V | 170V-270V ± 10V | 170V-270V ± 10V | 170V-270V ± 10V |
Output Voltage on Mains Mode | Same as input | Same as input | Same as input | Same as input |
Output Voltage on Backup Mode | 210V+10%, -15% | 210V+10%, -15% | 210V+10%, -15% | 210V+10%, -15% |
Output Frequency in Backup Mode | 5OHz + O.1HZ | 5OHz + O.1HZ | 5OHz + O.1HZ | 5OHz + O.1HZ |
Switching from mains to Backup and from Backup to Mains | Automatic | Automatic | Automatic | Automatic |
Output Waveform on Mains Mode | Same as input | Same as input | Same as input | Same as input |
Output Waveform on Backup Mode | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave |
Battery Charging Current | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah |
Charger | CCCV | CCCV | CCCV | CCCV |
PCU Overload/PCU Short Circuit | 110% / 300% | 110% / 300% | 110% / 300% | 110% / 300% |
PCU Transfer Time | <=15msec | <=15msec | <=15msec | <=15msec |
Available Market | AF, ME, CIS |
Designed for demanding applications, it ensures reliable power, efficient battery charging, and seamless transitions for optimal off-grid living. Choose from our range of models to suit your needs.
Offers reliable off-grid power with wide input voltage range, pure sine wave output, and advanced battery management. Ideal for compact energy needs.
Description | 500VA-12V | 1000VA-12V | 1500VA-24V | 2000VA-24V |
---|---|---|---|---|
Input Voltage (WIDE MODE) | 90V-290V ± 10V | 90V-290V ± 10V | 90V-290V ± 10V | 90V-290V ± 10V |
Input Range (NARROW MODE) | 170V-270V ± 10V | 170V-270V ± 10V | 170V-270V ± 10V | 170V-270V ± 10V |
Output Voltage on Mains Mode | Same as input | Same as input | Same as input | Same as input |
Output Voltage on Backup Mode | 220V+10%, -15% | 220V+10%, -15% | 220V+10%, -15% | 220V+10%, -15% |
Output Frequency in Backup Mode | 50Hz + O.1Hz | 50Hz + O.1Hz | 50Hz + O.1Hz | 50Hz + O.1Hz |
Switching from mains to Backup and from Backup to Mains | Automatic | Automatic | Automatic | Automatic |
Output Waveform on Mains Mode | Same as input | Same as input | Same as input | Same as input |
Output Waveform on Backup Mode | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave |
Battery Charging Current | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah |
Charger | CCCV | CCCV | CCCV | CCCV |
PCU Overload/PCU Short Circuit | 110% / 300% | 110% / 300% | 110% / 300% | 110% / 300% |
PCU Transfer Time | <=15msec | <=15msec | <=15msec | <=15msec |
Technology | DSPIC BASED DESIGN | DSPIC BASED DESIGN | DSPIC BASED DESIGN | DSPIC BASED DESIGN |
Auto Reset Feature | Yes | Yes | Yes | Yes |
Operating Temperature | -10°C to +45°C | -10°C to +45°C | -10°C to +45°C | -10°C to +45°C |
Voc Range | 15V-52V | 15V-52V | 30V-105V | 30V-105V |
Max PV Power | 5OOW | 10OOW | 15OOW | 20OOW |
Solar Current Max. | 32AMP ± 3A | 6OAMP ± 3A | 5OAMP ± 3A | 68AMP ± 3A |
Type of Charge | MPPT with Isolated Gate Drive | MPPT with Isolated Gate Drive | MPPT with Isolated Gate Drive | MPPT with Isolated Gate Drive |
Available Market | AF, ME, CIS |
Inverter ensures efficient power for off-grid living with automatic switching, pure sine wave output, and robust protection.
Description | 500VA-12V | 1000VA-12V | 1500VA-24V | 2000VA-24V |
---|---|---|---|---|
Input Voltage (WIDE MODE) | 90V-290V ± 10V | 90V-290V ± 10V | 90V-290V ± 10V | 90V-290V ± 10V |
Input Range (NARROW MODE) | 170V-270V ± 10V | 170V-270V ± 10V | 170V-270V ± 10V | 170V-270V ± 10V |
Output Voltage on Mains Mode | Same as input | Same as input | Same as input | Same as input |
Output Voltage on Backup Mode | 220V+10%, -15% | 220V+10%, -15% | 220V+10%, -15% | 220V+10%, -15% |
Output Frequency in Backup Mode | 50Hz + O.1Hz | 50Hz + O.1Hz | 50Hz + O.1Hz | 50Hz + O.1Hz |
Switching from mains to Backup and from Backup to Mains | Automatic | Automatic | Automatic | Automatic |
Output Waveform on Mains Mode | Same as input | Same as input | Same as input | Same as input |
Output Waveform on Backup Mode | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave |
Battery Charging Current | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah |
Charger | CCCV | CCCV | CCCV | CCCV |
PCU Overload/PCU Short Circuit | 110% / 300% | 110% / 300% | 110% / 300% | 110% / 300% |
PCU Transfer Time | <=15msec | <=15msec | <=15msec | <=15msec |
Technology | DSPIC BASED DESIGN | DSPIC BASED DESIGN | DSPIC BASED DESIGN | DSPIC BASED DESIGN |
Auto Reset Feature | Yes | Yes | Yes | Yes |
Operating Temperature | -10°C to +45°C | -10°C to +45°C | -10°C to +45°C | -10°C to +45°C |
Voc Range | 15V-52V | 15V-52V | 30V-105V | 30V-105V |
Max PV Power | 5OOW | 10OOW | 15OOW | 20OOW |
Solar Current Max. | 32AMP ± 3A | 6OAMP ± 3A | 5OAMP ± 3A | 68AMP ± 3A |
Type of Charge | MPPT with Isolated Gate Drive | MPPT with Isolated Gate Drive | MPPT with Isolated Gate Drive | MPPT with Isolated Gate Drive |
Available Market | AF, ME, CIS |
Provides dependable power for demanding off-grid applications with wide input voltage range, pure sine wave output, and efficient battery charging.
Description | 500VA-12V | 1000VA-12V | 1500VA-24V | 2000VA-24V |
---|---|---|---|---|
Input Voltage (WIDE MODE) | 90V-290V ± 10V | 90V-290V ± 10V | 90V-290V ± 10V | 90V-290V ± 10V |
Input Range (NARROW MODE) | 170V-270V ± 10V | 170V-270V ± 10V | 170V-270V ± 10V | 170V-270V ± 10V |
Output Voltage on Mains Mode | Same as input | Same as input | Same as input | Same as input |
Output Voltage on Backup Mode | 220V+10%, -15% | 220V+10%, -15% | 220V+10%, -15% | 220V+10%, -15% |
Output Frequency in Backup Mode | 50Hz + O.1Hz | 50Hz + O.1Hz | 50Hz + O.1Hz | 50Hz + O.1Hz |
Switching from mains to Backup and from Backup to Mains | Automatic | Automatic | Automatic | Automatic |
Output Waveform on Mains Mode | Same as input | Same as input | Same as input | Same as input |
Output Waveform on Backup Mode | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave |
Battery Charging Current | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah |
Charger | CCCV | CCCV | CCCV | CCCV |
PCU Overload/PCU Short Circuit | 110% / 300% | 110% / 300% | 110% / 300% | 110% / 300% |
PCU Transfer Time | <=15msec | <=15msec | <=15msec | <=15msec |
Technology | DSPIC BASED DESIGN | DSPIC BASED DESIGN | DSPIC BASED DESIGN | DSPIC BASED DESIGN |
Auto Reset Feature | Yes | Yes | Yes | Yes |
Operating Temperature | -10°C to +45°C | -10°C to +45°C | -10°C to +45°C | -10°C to +45°C |
Voc Range | 15V-52V | 15V-52V | 30V-105V | 30V-105V |
Max PV Power | 5OOW | 10OOW | 15OOW | 20OOW |
Solar Current Max. | 32AMP ± 3A | 6OAMP ± 3A | 5OAMP ± 3A | 68AMP ± 3A |
Type of Charge | MPPT with Isolated Gate Drive | MPPT with Isolated Gate Drive | MPPT with Isolated Gate Drive | MPPT with Isolated Gate Drive |
Available Market | AF, ME, CIS |
Delivers high-performance power for demanding needs with flexible input voltage, pure sine wave output, and advanced protection.
Description | 500VA-12V | 1000VA-12V | 1500VA-24V | 2000VA-24V |
---|---|---|---|---|
Input Voltage (WIDE MODE) | 90V-290V ± 10V | 90V-290V ± 10V | 90V-290V ± 10V | 90V-290V ± 10V |
Input Range (NARROW MODE) | 170V-270V ± 10V | 170V-270V ± 10V | 170V-270V ± 10V | 170V-270V ± 10V |
Output Voltage on Mains Mode | Same as input | Same as input | Same as input | Same as input |
Output Voltage on Backup Mode | 220V+10%, -15% | 220V+10%, -15% | 220V+10%, -15% | 220V+10%, -15% |
Output Frequency in Backup Mode | 50Hz + O.1Hz | 50Hz + O.1Hz | 50Hz + O.1Hz | 50Hz + O.1Hz |
Switching from mains to Backup and from Backup to Mains | Automatic | Automatic | Automatic | Automatic |
Output Waveform on Mains Mode | Same as input | Same as input | Same as input | Same as input |
Output Waveform on Backup Mode | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave |
Battery Charging Current | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah | Constant Charging approx 10% of the rated battery current in Ah |
Charger | CCCV | CCCV | CCCV | CCCV |
PCU Overload/PCU Short Circuit | 110% / 300% | 110% / 300% | 110% / 300% | 110% / 300% |
PCU Transfer Time | <=15msec | <=15msec | <=15msec | <=15msec |
Technology | DSPIC BASED DESIGN | DSPIC BASED DESIGN | DSPIC BASED DESIGN | DSPIC BASED DESIGN |
Auto Reset Feature | Yes | Yes | Yes | Yes |
Operating Temperature | -10°C to +45°C | -10°C to +45°C | -10°C to +45°C | -10°C to +45°C |
Voc Range | 15V-52V | 15V-52V | 30V-105V | 30V-105V |
Max PV Power | 5OOW | 10OOW | 15OOW | 20OOW |
Solar Current Max. | 32AMP ± 3A | 6OAMP ± 3A | 5OAMP ± 3A | 68AMP ± 3A |
Type of Charge | MPPT with Isolated Gate Drive | MPPT with Isolated Gate Drive | MPPT with Isolated Gate Drive | MPPT with Isolated Gate Drive |
Available Market | AF, ME, CIS |
Our off-grid inverters cater to remote locations and off-the-grid living. Ideal for diverse applications, these versatile solutions offer autonomy and reliable power, whether it's for our remote cabins, emergency backup, or sustainable living.
Explore our range of related products designed to complement your energy needs. From Inverters to Charge Controllers to Panels, we offer a comprehensive suite of products to enhance your power setup.